Based on standard 2-3/4" (70mm) thick panel.
Also available as 4" (100mm) thick configuration (click here for more information).

FACE SHEET
COMBINATIONS1
% LIGHT TRANSMISSION2 SKYROOF SOLAR HEAT
GAIN COEFFICIENT3
SOLAR HEAT GAIN4
(Btu/h• ft2)
EXTERIOR
COLOR
INTERIOR
COLOR
0.53 "U"5 0.29/
0.23
"U"
0.22/
0.14
"U"
0.18/
0.10
"U"
0.05 "U" 0.53 "U" 0.29/
0.23
"U"
0.22/
0.14
"U"
0.18/
0.10
"U"
0.05 "U" 0.53 "U" 0.29/
0.23
"U"
0.22/
0.14
"U"
0.18/
0.10
"U"
.05 "U"
Greenish Blue White 25 14 5 3 107 0.37 0.18 0.10 0.07 0.11 104 52 30 20 31
Aqua White 29 17 6 4 127 0.37 0.19 0.10 0.07 0.11 106 54 30 20 31
Rose White 30 18 6 4 127 0.38 0.19 0.10 0.07 0.11 109 54 30 20 31
Ice Blue White 35 20 8 6 157 0.44 0.22 0.11 0.07 0.12 126 62 32 20 34
Greenish Blue Crystal 37 20 7 4 157 0.47 0.21 0.13 0.08 0.13 133 59 37 22 37
Aqua Crystal 43 23 7 4 187 0.49 0.22 0.13 0.08 0.12 138 62 37 22 34
Rose Crystal 48 24 8 5 187 0.50 0.23 0.13 0.08 0.13 143 64 37 22 37
Ice Blue Crystal 53 27 10 6 207 0.59 0.25 0.15 0.09 0.14 168 72 42 25 40
White Crystal 30 18 12 8 157 0.37 0.17 0.10 0.07 0.10 106 49 30 20 28
White White 20 15 8 5 12 0.30 0.16 0.09 0.06 0.09 86 44 25 17 26
Crystal White 35 20 12 8 15 0.42 0.23 0.11 0.07 0.11 119 64 32 20 31
Crystal Crystal 50 30 15 10 20 0.55 0.27 0.14 0.09 0.12 156 77 40 25 34
Crystal SWC6 White 29 16 9 6 137 0.40 0.20 0.13 0.08 0.11 114 57 37 23 31
Crystal SWC Crystal 44 22 11 8 207 0.52 0.24 0.15 0.09 0.12 148 68 43 26 34
1 Most common combination; many other combinations available.
2 Approximate values by ASTM E-972. Light transmission values over 30% not recommended for most applications.
3 At 0° incident angle. Numbers for various panels are calculated based on tests.
Shading Coefficient (SC) is equal to 1.15 times the Solar Heat Gain Coefficient (SHGC).
4 For Design Day of August 21, Noon, Horizontal, Lat. 40. Expressed as Btu/(h•ft2). DS glass would be 247.
5 U-values determined by NFRC test method (ASTM C-236, E-1423 and C-1199 at certified lab).
Expressed as Btu/(ft2•h•°F) for aluminum grid / thermally broken grid, nominal 12" x 24".
Perimeter aluminum excluded. Test temperature at 15 mph wind (6.7 m/s): 0°F (-18°C) cold side & 70°F (21°C) warm side.
6 Type A and SWC face sheets are similar in light transmission and solar heat gain properties.
White High-Impact same as standard white.
7 Estimated based on standard engineering calculations.
Check with our Technical Services Department for further clarification. Since this table is of a very technical nature,
please consult your heating and ventilation engineer for proper interpretation.
Metric U-Value Conversions
English 0.53 0.29 0.23 0.22 0.18 0.14 0.10 0.05 Btu/(hr/ft2/°F)
SI 3.01 1.65 1.31 1.25 1.02 0.79 0.57 0.28 W/(m2K)
©2011 Structures Unlimited, Inc. All rights reserved.